MC 80 DXMicroscope CameraOperating Manual
Carl Zeiss MC 80 DXX B 40-036 e 03/99
MC 80 DXCarl ZeissB 40-036 e 03/99 1-1DESCRIPTIONContents1 DESCRIPTION...
Carl Zeiss MC 80 DX1-2 B 40-036 e 03/99
MC 80 DXCarl ZeissB 40-036 e 03/99 1-31 DESCRIPTION1.1 Designation, Intended UseModel designation: MC 80 DX Microscope CameraThe MC 80 DX Microscope
Carl Zeiss MC 80 DX1-4 B 40-036 e 03/991.3 System OverviewFig. 1-1 MC 80 DX Microscope Camera outfit
MC 80 DXCarl ZeissB 40-036 e 03/99 1-5MC 80 DX Microscope Camera outfit Catalogue No.1 MC 80 DX control console 456048-0000-0002 MC 80 DX camera bod
Carl Zeiss MC 80 DX1-6 B 40-036 e 03/991.4 Overview of image positions (tube connections), appropriate camera tubes andmicroscope standsImage positi
MC 80 DXCarl ZeissB 40-036 e 03/99 1-7Image position (tubeconnection)Cat. No. of camera tube Microscope stand44 mm 452910-0000-000452911-0000-000452
Carl Zeiss MC 80 DX1-8 B 40-036 e 03/991.5 Specification(1) Dimensions (Width Depth Height)MC 80 DX camera body...
MC 80 DXCarl ZeissB 40-036 d 03/99 2-1OPERATIONContents2 OPERATION...
Carl Zeiss MC 80 DXII B 40-036 e 03/99Familiarity with the contents of this manual is a prerequisite for operating the equipment. Thereforestudy the
Carl Zeiss MC 80 DX2-2 B 40-036 d 03/99IllustrationsFig. 2-1 Attaching the camera adapter and the projection lens...
MC 80 DXCarl ZeissB 40-036 d 03/99 2-32 OPERATIONThe MC 80 DX Microscope Camera comes packed together with its accessories. Remove all modulesfrom t
Carl Zeiss MC 80 DX2-4 B 40-036 d 03/99(2) Inserting the projection lensPush the projection lens (2-1/1, 2) into the camera adapter (2-1/3, 4, 5, 6)
MC 80 DXCarl ZeissB 40-036 d 03/99 2-52.1.2 The 35 mm Mot DX film cassette(1) Removing the film cassetteUse your two hands to grasp the film cassett
Carl Zeiss MC 80 DX2-6 B 40-036 d 03/99 The film and the cartridge are lying flat onthe support ! The film leader is pulled out until theinsertion
MC 80 DXCarl ZeissB 40-036 e 03/99 2-7(3) Attaching the film cassetteHold film cassette with both hands on the right and left of the camera body. Th
Carl Zeiss MC 80 DX2-8 B 40-036 e 03/992.1.3 MC 80 DX Microscope Camera with M 4 5” large-frame attachmentThe equipment is designed to be installe
MC 80 DXCarl ZeissB 40-036 e 03/99 2-9(3) Attaching the MC 80 DX camera body Attach the MC 80 DX camera body (2-5/5) onto the camera adapter with i
Carl Zeiss MC 80 DX2-10 B 40-036 e 03/992.2 Switches and Connectors(1) Connecting the camera body Push plug of camera body (2-2/5) or (2-5/10)into
MC 80 DXCarl ZeissB 40-036 e 03/99 2-11(5) Switching on the control consoleTo switch the control console on or off, actuate the power on/off switch
MC 80 DXCarl ZeissB 40-036 e 03/99 IIICONTENTSPageINTRODUCTION...
Carl Zeiss MC 80 DX2-12 B 40-036 e 03/992.3.1 Exposure control for 35 mm framesWhen you use 35 mm film, the windows displaythe following information
MC 80 DXCarl ZeissB 40-036 e 03/99 2-132.3.3 AUTO mode (Automatic exposure control)Pressing the <AUTO> button activates automaticexposure cont
Carl Zeiss MC 80 DX2-14 B 40-036 e 03/99The following multiplying factors apply to the selected exposure corrections:Exposure correction Multiplying
MC 80 DXCarl ZeissB 40-036 e 03/99 2-152.3.5 TIME mode (long-time exposure control) Pressing the <TIME> button activates (long) TIME exposure
Carl Zeiss MC 80 DX2-16 B 40-036 e 03/992.3.7 Multiple exposure Multiple exposure is only possible with 35 mmfilm. To activate the multiple exposur
MC 80 DXCarl ZeissB 40-036 e 03/99 2-172.3.8 Exposure interruption / Film advance Pressing the <WIND> button stops any runningexposure. In ca
Carl Zeiss MC 80 DX2-18 B 40-036 e 03/99 Input of the speed of non-DX-coded 35 mmfilmand of large-frame sheet film: Press <ISO> button for
MC 80 DXCarl ZeissB 40-036 e 03/99 2-192.4 Exposure Control for Large Frames With the M 4 5” camera attachmentinstalled, pressing the <4 5”&
Carl Zeiss MC 80 DX2-20 B 40-036 e 03/992.5 Warning MessagesIn the AUTO mode, the following warning messages may appear on the LCD display: AUTO OV
MC 80 DXCarl ZeissB 40-036 e 03/99 2-212.6 Data Exposure via Control Console (for 35 mm frames only) If the D4 databack is installed on the 35 mmM
Carl Zeiss MC 80 DXIV B 40-036 e 03/992.6 Data Exposure via Control Console (for 35 mm frames only)...2-212.
Carl Zeiss MC 80 DX2-22 B 40-036 e 03/992.6.2 Selecting the data format While the symbol of the selected data field,“PIC” or “BRI”, is blinking, th
MC 80 DXCarl ZeissB 40-036 e 03/99 2-232.6.2.3 Data format F-Count (frame counter) This data format is coupled to film advance.Every film advance i
Carl Zeiss MC 80 DX2-24 B 40-036 e 03/992.6.2.5 Data exposure via keyboardThe data for the Keyboard and Keyboard-Scale formats cannot be entered via
MC 80 DXCarl ZeissB 40-036 e 03/99 2-25 Before, the length L in the specimen plane must be computed by the formula given below, for therespective o
Carl Zeiss MC 80 DX2-26 B 40-036 e 03/992.6.2.6 OFF state In this state, the data field displaying the "OFF" message does not contain any
MC 80 DXCarl ZeissB 40-036 e 03/99 2-272.6.3 Data input in the selected formatDuring data input, the “BRI” or “PIC“ symbol for the respective data f
Carl Zeiss MC 80 DX2-28 B 40-036 e 03/992.6.3.2 In the Keyboard and Keyboard-Scale data formats Pressing the <SELECT> button enables datainpu
MC 80 DXCarl ZeissB 40-036 e 03/99 2-292.6.3.3 Examples of data input(1) Time updating in the BRI data field with data format DHM From 08:13 to 13:
Carl Zeiss MC 80 DX2-30 B 40-036 e 03/99(2) Input of scaling bar in the PIC data field with Keyboard-Scale data format Enter the length of the scal
MC 80 DXCarl ZeissB 40-036 e 03/99 2-312.6.4 Location of the PIC data fieldThe location of the PIC data field inside the micrograph is not marked on
MC 80 DXCarl ZeissB 40-036 e 03/99 VPerfect Micrographs in a Few StepsBefore the first startup, read the section "Safe Use of the Equipment&quo
Carl Zeiss MC 80 DX2-32 B 40-036 e 03/99Frame size reticle in eyepiece of microscopeMC 2.5 /dia. 26 mm454075-0000-000PL 10 /18 Br. foc.E-PL 10 /20
MC 80 DXCarl ZeissB 40-036 e 03/99 2-33 Carefully select the specimen area of interest and focus on it. If the focusing crosshairs and thespecimen
Carl Zeiss MC 80 DX2-34 B 40-036 e 03/99Cut the film tongue always as specified in DIN4536 or ISO 1977 (Fig. 2-9). The cut must not run across any
MC 80 DXCarl ZeissB 40-036 e 03/99 2-352.8.2.2 Correcting the color balance Place a CC filter of the color complementary to the color bias on the t
Carl Zeiss MC 80 DX2-36 B 40-036 e 03/99mounts, or picture file cards).Important data characterizing a micrograph (e.g. the scaling bar) belongs in
MC 80 DXCarl ZeissB 40-036 e 03/99 2-372.8.4 Darkfield and fluorescence micrographyCompared with common (brightfield) micrography, the following spe
Carl Zeiss MC 80 DX2-38 B 40-036 e 03/992.8.5 Exposure times and filtersThe "UNDER" warning (see section 2.5) appears in case of 35 mm fil
MC 80 DXCarl ZeissB 40-036 e 03/99 3-1CARE AND MAINTENANCEContents3 CARE AND MAINTENANCE ...
Carl Zeiss MC 80 DX3-2 B 40-036 e 03/99
MC 80 DXCarl ZeissB 40-036 e 03/99 3-33 CARE AND MAINTENANCE3.1 CareThe MC 80 DX Microscope Camera requires no care beyond the following precautions
Carl Zeiss MC 80 DXVI B 40-036 e 03/99Safe Use of the EquipmentThe MC 80 DX Microscope Camera including its original accessories may only be used fo
Carl Zeiss MC 80 DX3-4 B 40-036 e 03/993.2 FusesThe two fuse holders (3-1/2) are inside the powerinput socket/fuse combination (3-1/1) at the rearof
MC 80 DXCarl ZeissB 40-036 e 03/99 3-53.4 Requesting ServiceAll repairs of mechanical, optical or electronic components inside the instrument and of
Carl Zeiss MC 80 DX3-6 B 40-036 e 03/99
MC 80 DXCarl ZeissB 40-036 e 10/98 A-1ANNEX- List of Acronyms and Abbreviations- Subject Index- Certification acc. to DIN ISO 9001 / EN 46001- Decla
Carl Zeiss MC 80 DXA-2 B 40-036 e 03/99
MC 80 DXCarl ZeissB 40-036 e 10/98 A-3List of Acronyms and AbbreviationsBF BrightfieldBr. High eyepoint eyepiece (for eyeglass wearers)BRI Bridge (d
Carl Zeiss MC 80 DXA-4 B 40-036 e 03/99Subject IndexAAUTO and MAN(ual) modes...
MC 80 DXCarl ZeissB 40-036 e 03/99 A-5Film advance...
Carl Zeiss MC 80 DXA-6 B 40-036 e 03/99PPIC data field...
MC 80 DXCarl ZeissB 40-036 e 03/99 VIIIf the protective measures are found to be no longer effective, the equipment must beswitched off and safeguar
Carl Zeiss MC 80 DXVIII B 40-036 e 03/99Notes on WarrantyThe manufacturer warrants that the product has been supplied in a state free from defects o
MC 80 DXCarl ZeissB 40-036 e 03/99 IXOverall View of the MC 80 DX Microscope Camera